When required by the customer, Xsis
oscillators can be subjected to the following tests on a
100% basis. PDA for burn-in is in accordance with the
requirements of MIL-PRF-55310 for class B products.
|
| Non-Destructive Bond Pull |
MIL-STD-883, Method 2023 ( PDA = 2% or 1 wire whichever is greater ) |
| Internal Visual |
MIL-STD-883, Method 2017, Class B |
| Stabilization Bake |
MIL-STD-883, Method 1008, Cond. C, 48 Hours
Minimum |
| Temperature Cycling |
MIL-STD-883, Method 1010, Cond. C |
| Constant Acceleration |
MIL-STD-883, Method 2001, Cond. A, Y1 only, (
5000 G ) |
| Seal ( fine and gross leak ) |
MIL-STD-883, Method 1014 |
| PIND |
MIL-STD-883, Method 2020, Cond. B |
| Radiographic |
MIL-STD-883, Method 2012 |
| Electrical Tests |
MIL-PRF-55310, Class B |
| Burn-in |
+125
°C
, Nominal Supply Voltage and Burn-in
Load, 240 Hours Minimum |
| Electrical Tests |
MIL-PRF-55310, Class B |
|