883B SCREENING
( Same as MIL-PRF-55310, Class B Screening )
|
When 883B Screening is specified, Xsis oscillators are subjected to the following tests on a 100% basis. PDA for burn-in is in accordance with the requirements of
MIL-PRF-55310 for Class B products.
|
| |
|
Internal Visual
|
MIL-STD-883, Method 2017,
Class B |
Stabilization Bake
|
MIL-STD-883, Method 1008,
Cond. C, 24 Hours Minimum |
Temperature Cycling
|
MIL-STD-883, Method 1010,
Cond. B |
Constant Acceleration
|
MIL-STD-883, Method 2001,
Cond. A, Y1 only, ( 5000 G ) |
Seal ( fine and gross leak )
|
MIL-STD-883, Method 1014
|
Electrical Tests
|
MIL-PRF-55310, Class B
|
Burn-in |
+125 °C, Nominal Supply
Voltage and Burn-in Load, 160 Hours Minimum
|
Electrical Tests
|
MIL-PRF-55310, Class
B |
|
| |